Cases/NVH/C04
NVHMajor-appliance / cleaning-appliance production lines

Appliance Sound-Power Compliance at End of Line

01

Pain Points

  • !Washers/AC units/range hoods must run sound power for the energy label — heavy manual computation.
  • !A-weighting, octave bands, environmental correction, and surface synthesis chain together and must be recomputed for every unit.
  • !PASS/FAIL and the end-of-line report are scattered across multiple tools.
02

The Tinia Approach

Per-channel A-weighting + one-third octave, synthesize L_WA over the measurement surface, and auto-judge PASS/FAIL — production sampling reuses the same workflow directly.

Channel splitA-weightingSound levelOne-third octaveSynthesize L_WAPASS/FAIL
03

Nodes Used

Channel Splitchannel_split
Split the synchronized multi-mic channels
Frequency Weightingweighting_filter
A-weighting
Sound Level Meterlevel_meter
Sound level at each point
Octave Analysisoctave_analysis
One-third octave spectrum
Indicator Mathindicator_math
Synthesize L_WA over the measurement surface
Spec Limit Checkspec_limit_check
PASS / FAIL evaluation

Core nodes; add or remove steps as needed for your data and standards — the node graph is always editable.

04

Expected Output

  • A single L_WA sound-power value (dB) + one-third-oct spectrum.
  • PASS / FAIL evaluation and an end-of-line report view.
  • A standardized workflow reusable for production sampling.
Reference Standards / Engineering PracticeIEC 60704 series · ISO 3744